Abstract

Root canal preparation leads to deviation of the canal anatomy causing canal transportation which affects the success of the treatment. Cone Beam Computed Tomography (CBCT) is a non invasive imaging technique to analyse the shape of the root canal before and after the preparation. The purpose of this study was to investigate and evaluate the canal transportation in curved mandibular molar root canals and centering ability of Reciproc and One Shape file systems after instrumentation using CBCT. Twenty mandibular molars were taken and allocated into two groups (n=10): Group 1-One Shape and Group 2-Reciproc. The canals were then scanned using CS 3D CBCT scanner (Carestream) before and after preparation, to assess the transportation and centering values at different levels respectively from the apex. The data gathered were then assessed statistically with Mann-Whitney test. Analysis revealed that Reciproc and One Shape showed statistically no significant difference in terms of canal transportation and centering ability (p>0.05). One shape and Reciproc performed similar in terms of canal transportation & centering ability.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.