Abstract

The aim of the study is to present the techniques and results of numerical-field analysis of the magnetic losses power in a turbogenerator with a complex structure of the stator core. The computational method is based on the search for the maxima of the magnetic induction values in the teeth and yoke of the core by enumerating a multitude of repeating minisectors. From the distribution of these maxima, its rms values are determined for the indicated regions of the core as a whole, and the magnetic losses powers are calculated from it. The method allows to display the calculated models of cores of any shape and practically does not require simplification of their geometric structure. A comparative analysis of the power of magnetic losses in idling and rated load for the core variants in the absence and presence of axial ventilation channels in its yoke and teeth is carried out.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.