Abstract

The pixel detector of the Compact Muon Solenoid (CMS) experiment consists of three barrel layers and two endcap disks at each side of the barrel section. The detector was installed in summer 2008, commissioned with the readout chip internal pulse generator, and used in cosmic ray trigger data taking in a 3.8 T magnetic field. Despite the excellent detector performance some problems arose after installation. In about a year we went through a complete and important sequence of steps that go from the insertion of the detector in CMS, calibration, running, extraction, maintenance, to the re-insertion, recalibration and final running. Currently 98.6% of the whole pixel detector is fully functional and results on detector performance are found to be in line with the design specifications.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.