Abstract

Abstract Thirteen chemists representing twelve laboratories participated in a collaborative study for the quantitative determination of ethyl acetate and fusel oil by GLC. The results on four samples containing various amounts of ethyl acetate and fusel oil were compared with the official AOAC procedures. For all samples, the standard deviations were lower with GLC. Collaborators preferred the GLC procedure because the simultaneous determination of ethyl acetate and n-propyl, iso-butyl, and isoamyl alcohols is possible. Results from preliminary work performed on the quantitative determination of acetaldehyde by GLC were encouraging. It is recommended that the proposed GLC procedure for the quantitative determination of ethyl acetate and fusel oil be adopted as official, first action, and that work be continvied on the determination of acetaldehyde by GLC.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.