Abstract

Pulmonary vein electrical isolation (PVI) is an effective treatment for atrial fibrillation (AF). However, recurrence of pulmonary vein (PV) conduction after ablation may limit long-term success. We sought to determine the clinical predictors of acute PV reconnection during PVI and assess the long-term clinical outcomes associated with this phenomenon. We studied all patients with AF referred for PVI between November 2000 and August 2004. Over the course of the study period, PVI of arrhythmogenic PVs was performed segmentally using a 4-mm tip (52 degrees , 40 W, up to 90 seconds) or 8-mm tip catheter (50 degrees , 70 W, up to 60 seconds). PVI was defined as entry and exit block using a multipolar Lasso catheter. All veins were resampled to confirm isolation after 20-60 minutes. AF control was defined as no AF on or off a previously ineffective antiarrhythmic drug. Follow-up data included transtelephonic monitoring and clinical data collection from patient interviews. There were 424 patients who underwent isolation of 1,347 PVs during the study period. Acute reconnection of at least one PV occurred in 211 (50%) of the 424 patients and 326 (24%) of 1,347 of the PVs targeted. The left superior PV was most likely to acutely recover conduction compared with the other veins (left superior 31%, right superior 26%, right inferior 22%, left inferior 24%; P = .03). Patients with acute reconnection were more likely to be older, have a larger left atrium, have a history of hypertension or obstructive sleep apnea, and demonstrate persistent AF. After a single procedure, AF control was achieved in 153 (70%) of the 213 patients who demonstrated acute PV reconnection compared with 148 (73%) of 211 patients without acute PV reconnection observed (P = .52). Acute return of PV conduction is common after successful PVI and is more likely to occur in older patients with nonparoxysmal AF, hypertension, a large left atrium, and sleep apnea. There was no significant difference in acute PV reconnection between the 4-mm and 8-mm tip RF catheter despite differences in power and duration of energy delivery. Furthermore, there was no effect of PV reconnection on long-term AF control after repeated disconnection was performed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.