Abstract

A 5-year clinical comparison between silver palladium alloys (Albacast and Ney 76) and gold alloy (Firmilay) was conducted. Clinical evaluations for the castings of these materials placed in the same patients, were recorded immediately after cementation, at 3 months, 6 months, 1.5 years, 3 years, and 5 years. The changes in surface tarnish, discoloration, polish, and plaque accumulation was compared. The results indicated that gold alloys responded slightly better than Ney 76 alloy, but similar to Albacast alloy with adequate correlation between the four criteria evaluated.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.