Abstract

Objective To evaluate the postoperative outcomes and intraoperative and postoperative complications of clear lens extraction (CLE) with posterior chamber intraocular lens (IOL) implantation in highly myopic eyes. Design Retrospective case series. Participants One hundred seven patients (190 eyes) who had undergone CLE with posterior chamber IOL implantation and who had been observed for at least 3 years after surgery. Methods Medical records of patients who had undergone CLE with posterior chamber IOL implantation to treat high myopia (axial length >26.00 mm) over 7 years (January 1990 to December 1996) were reviewed. Visual acuity and refractive error were assessed before and after surgery, and perioperative, intraoperative, and postoperative complications were recorded. Main outcome measures Axial length, preoperative and final best spectacle-corrected visual acuity (BSCVA), preoperative and postoperative spherical equivalent (SE), argon laser treatments, surgical complications, neodymium:yttrium–aluminum–garnet (Nd:YAG) laser capsulotomy, retinal detachment (RD), time from surgery or Nd:YAG capsulotomy to RD, subfoveal choroidal neovascularization (CNV), and follow-up period. Results The mean postoperative follow-up period was 4.78 years (range, 3.10–8.03 years). Final BSCVA was better than preoperative BSCVA in 159 eyes (83.68%), equal in 24 eyes (12.63%), and worse in 7 eyes (3.68%). Postoperative BSCVA was 20/40 or better in 136 eyes (71.60%) vs. 52 eyes (27.36%) before surgery ( P<0.001). The mean final postoperative SE was −1.22 diopters. The risk of Nd:YAG laser capsulotomy was 77.89%. The incidence of RD was 2.10%; retinal reattachment was achieved in all cases, and none of these eyes had worse final BSCVA than before surgery. Subfoveal CNV developed in 4 eyes (2.10%) of 3 patients; all of these eyes presented with a macular lacquer crack. Conclusions Clear lens extraction with posterior chamber IOL implantation has good outcomes with acceptable predictability and improvement in best-corrected visual acuity. During follow-up, patients tended to remain stable, and the risk of retinal detachment was low. We attribute our favorable results to careful patient selection and follow-up.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.