Abstract
Circumferential adjustment of the position of a two-dimensional ultrasound (US) probe around the neck has been recommended as a strategy for reducing the potential for unintentional common carotid artery puncture during internal jugular venous (IJV) cannulation. We obtained multiple high-resolution US images bilaterally from the necks of 107 adult subjects and analyzed these to determine the degree to which this strategy permits identification of a pathway from the skin to the IJV that minimizes venoarterial overlap while maximizing venous target (angular) width. The method consistently permitted identification of an approach to the IJV superior to that obtainable with any one of four popular surface anatomy-based ("blind") approaches and was even more powerful if used in concert with a US-guided 1) adjustment of the degree of head rotation, 2) choice between a high and low approach, and 3) choice between the right and left IJV. Use of a high-resolution US imaging device also permitted identification of the precise boundaries of additional cervical anatomic structures (nontarget vessels, lymph nodes, and the thyroid gland) potentially relevant to selection of an optimal approach to the IJV.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.