LC separation of carboprost diastereomers in bulk drug was developed and validated using normal-phase amylose stationary phase Chiralpak AD-H. The effect of the organic modifiers, namely 2-propanol and ethanol in the mobile phase was optimized in order to obtain the best separation. The retention time of (R)-carboprost and (S)-carboprost were 15.3 and 17.1 min, respectively. Calibration curves were linear over the range of 0.2–1.0%, with the regression coefficient (R2) of 0.9997. The limit of detection (LOD) and the limit of quantification (LOQ) were 0.07 and 0.2%, respectively. The method was accurate, precise and suitable to use for the purpose of controlling unwanted (R)-isomer in the carboprost active pharmaceutical ingredient. This method can be successfully applied to the analysis of chiral purity of carboprost in pharmaceutical bulk drug samples.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.