Abstract
High radiation doses of stereotactic radiosurgery (SRS) for brain metastases (BM) can increase the likelihood of radiation necrosis (RN). Advanced MRI sequences can improve the differentiation between RN and tumor progression (TP). To use saturation transfer MRI methods including chemical exchange saturation transfer (CEST) and magnetization transfer (MT) to distinguish RN from TP. Prospective cohort study. Seventy patients (median age 60; 73% females) with BM (75 lesions) post-SRS. 3-T, CEST imaging using low/high-power (saturation B1 =0.52 and 2.0 μT), quantitative MT imaging using B1 =1.5, 3.0, and 5.0 μT, WAter Saturation Shift Referencing (WASSR), WAter Shift And B1 (WASABI), T1 , and T2 mapping. All used gradient echoes except T2 mapping (gradient and spin echo). Voxel-wise metrics included: magnetization transfer ratio (MTR); apparent exchange-dependent relaxation (AREX); MTR asymmetry; normalized MT exchange rate and pool size product; direct water saturation peak width; and the observed T1 and T2 . Regions of interests (ROIs) were manually contoured on the post-Gd T1 w. The mean (of median ROI values) was compared between groups. Clinical outcomes were determined by clinical and radiologic follow-up or histopathology. t-Test, univariable and multivariable logistic regression, receiver operating characteristic, and area under the curve (AUC) with sensitivity/specificity values with the optimal cut point using the Youden index, Akaike information criterion (AIC), Cohen's d. P < 0.05 with Bonferroni correction was considered significant. Seven metrics showed significant differences between RN and TP. The high-power MTR showed the highest AUC of 0.88, followed by low-power MTR (AUC=0.87). The combination of low-power CEST scans improved the separation compared to individual parameters (with an AIC of 70.3 for low-power MTR/AREX). Cohen's d effect size showed that the MTR provided the largest effect sizes among all metrics. Significant differences between RN and TP were observed based on saturation transfer MRI. 3 Technical Efficacy: Stage 2.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.