Abstract

The purpose of this research is to establish the type of corrosive environment responsible for brittle fracture of suspension composite insulators. A series of Fourier transform infrared spectroscopy (FTIR) experiments has been performed to identify chemical functionalities formed during the degradation process of composite insulators affected by brittle fracture. It has been shown that the brittle fracture process is caused by the formation of nitric acid either outside or inside an insulator leading to the stress corrosion cracking of the glass/polymer composite rod material. Nitrate has been detected on the composite fracture surfaces inside a 115 kV suspension composite insulator which failed in service by brittle fracture.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.