Abstract

New values of neutron fluxes and spectral parameters f and α were determined experimentally in all irradiation devices of the TRIGA Mark I IPR-R1 nuclear research reactor at Nuclear Technology Development Centre (CDTN), Belo Horizonte, Brazil. Sets of monitors Au, Fe, Zn and Zr were irradiated bare and Cd-covered, according to "Cd-ratio for multi-monitor" method. Values were validated by analysing the certified reference material BCR-320R irradiated in chosen channels. The calculations were made based on irradiation channel values and the average values of the Carousel. The results of E n -score point out that the k 0-method is producing reliable results. From now on, the values of mass fractions in several matrices, the production and studies with radioisotopes will be more accurate and the activities calculated more precisely.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.