Abstract

X-ray photoelectron spectroscopy/electron spectroscopy for chemical analysis (XPS/ESCA) is being widely used in failure analysis of semiconductor industries and wafer fabrication, as it is able to provide not only elemental information, but also chemical binding information. For example, using its fingerprint of C=O, we are able to identify possible root causes of carbon contamination in wafer fabrication (fab). In wafer fab, it is also being successfully used in failure analysis for Al fluorides on microchip Al bondpads. It is well known fact that it is difficult or impossible for us to fully free fluorine (F) from Al bondpads if F-based chemical gases such as CF <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">4</sub> and CHF <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3 </sub> are used for Al bondpad opening process in wafer fab. However, it is possible to reduce and control the F contamination to within the background/baseline level, which will not affect the bonding process at assembly houses

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.