ABSTRACT: Detection characteristics of perilla seeds exposed to electron beam doses of 0 to 2 kGy were investigated. DNA comet assay, photostimulated luminescence (PSL) and thermoluminescence (TL) measurements, and hydrocarbon determinations by GC‐MS were carried out. The irradiated samples showed comets with longer tails (152 ± 6 mm) than did nonirradiated samples (35 ± 11 mm). PSL values (photon counts) for the irradiated samples were more than 7865; whereas those of nonirradiated samples were less than 294. TL ratios (Glow 1/Glow 2) obtained from nonirradiated samples were less than 0.01 and above 0.48 from irradiated ones. The prominent radiation‐induced hydrocarbons were 16:2, 16:3, 17:1, and 17:2, of which 16:2 was the most abundant.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.