Abstract

Modern small-sized spectrometers are mainly designed by the Czerny–Turner scheme with a flat diffraction grating or, if the goal is to obtain the maximum aperture at the expense of resolution, by the scheme with a concave diffraction grating. In such spectrometers, the spectrum is registered by photodiode array. In this work, we provide an overview of characteristics of the compact spectrometers developed by our group. These spectrometers use caseless linear photodiode arrays for spectrum registration that eliminates the reflection of radiation from the cover glass of the photodiode array and reduces stray light. The tightness of the housing of spectrometers prolongs their service life. The parameters of the spectrometer modifications designed according to the Czerny–Turner scheme are given. The main advantage of the spectrometer of this type is the low stray light inside the device and the same spectral resolution throughout the spectral range. Aberrations limit the working aperture in the Czerny–Turner scheme to 1/6. The scheme with a flat field allows operation with a larger working aperture. Three modifications of the spectrometer have been developed according to this scheme; a description of their main parameters is given. The results of experimental comparison of the light gathering power and spectral resolution of spectrometers with different optical schemes, as well as the examples of their application, are presented. Devices designed according to the Czerny–Turner scheme are used in atomic emission and atomic absorption spectral analysis and in spectrophotometry for registration of absorption spectra of condensed media. The spectrometers with flat field are used for recording luminescence and Raman spectra of minerals. The developed compact spectrometers can work in a spectral range of 190–1100 nm with the width of the recorded spectral range from 70 to 1000 nm; the best spectral resolution is 0.1 nm, the stray light level is less than 0.05%, and the maximum measured optical density exceeds 3. Owing to a large working aperture of 1 : 2.1, the flat field spectrometers have an increased light gathering power.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.