Abstract

Purpose: Point-like <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">22</sup> Na radioactive sources have been widely used for checking radiation detectors that measure annihilation photons and for evaluating PET scanners. We developed new types of <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">22</sup> Na point-like radioactive sources that are expected to be more symmetric than conventional source types in the angular distribution of the emitted photons. The purpose of this study is to use Monte Carlo simulation to investigate the basic characteristics of the photons emitted from the new type <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">22</sup> Na point-like radioactive sources. Methods: Two new types of <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">22</sup> Na point-like sources, a cylinder type and a sphere type, were considered in comparison with two conventional source types, a disk type and a cube type. The angular distribution and energy spectra of the emitted 0.511 MeV annihilation photons and 1.275 MeV gamma rays were calculated using a Monte Carlo code based on Geant4. Results: The angular distribution of the emitted photons was more symmetric in the new type point-like sources than in the conventional types. The asymmetry of the angular distribution of the unscattered 0.511 MeV annihilation photon pairs counted in coincidence was 0.1 ±0.1% and 1.6±0.1% in the sphere and cylinder types, compared with 4.1±0.1% and 22.6±0.1% for the cube and disk types. The scatter components around the 0.511 MeV photopeaks in the new source types were typically less than 2/3 and 1/2 of those in the disk and cube types, respectively. Conclusion: The new point-like <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">22</sup> Na sources offer a more symmetric angular distribution of the emitted photons with fewer scatter components. They are useful for applications where the symmetry of the emitted photons is crucial.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.