Abstract

This paper describes a basic mechanism of Ag contact erosion by DC arc at the beginning of the contact break in low-voltage switch. We focused on the relationship between the contact erosion and the arc duration, and found that there is the contact erosion Mb, which is generated immediately after the start of break and does not depend on the arc duration but depends on approximately square of the current at the start of break. We considered that the Mb is the contact erosion due to the bridge formation at the beginning of the break, and the bridge formation depends on electrode heating at the final contact point. We also clarified the rate of the contact erosion at the beginning of the break is large against the total contact erosion. Especially, this rate reaches 90% in maximum case of this paper.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.