SummaryIt has been found that the addition of a whirl velocity component to an otherwise axial flow in a conical diffuser can lead to improvements in static pressure recovery and in efficiency, according to a restricted definition. Diffusers of total conical angle 10, 20 and 30 deg. were tested in detail; improvements were evident only in the last two, which would otherwise have suffered from flow separation problems caused by their relatively large divergence angles. The agency for improvement seems to be a beneficial redistribution of axial velocities.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.