Abstract

The purpose of this study is to assess the usefulness of the dynamic change in T/QRS ratio in fetal electrocardiograms in predicting the fetal condition when repetitive variable decelerations are seen in intrapartum cardiotocograms. We investigated the relationship, using linear regression and Wilcoxon's test, between T/QRS and blood gas values, catecholamine concentrations, and blood pressure during repetitive cord compression in five chronically instrumented lamb fetuses. T/QRS during cord compression correlated significantly (p less than 0.01) with fetal arterial pH (r = -0.7711), norepinephrine concentration (r = 0.7551), and duration of elevated blood pressure during compression (r = -0.8619). Fetal arterial pH and base excess were lower, the duration of elevated blood pressure during compression was shorter, and carbon dioxide partial pressure and catecholamine concentrations were higher in the stage with higher (greater than 0.50) T/QRS during compression (p less than 0.005). We can estimate the severity of fetal distress by measuring T/QRS near the bottom of the decelerations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.