Abstract

<p>Cable corrosion has been becoming significant issues for the bridge structures having with cable or hanger materials, such as suspension bridges, cable-stayed bridges, tied arch bridges and so on. Many of these bridges, which were built in 1980s and 90s, are possibly surviving under the cable corrosion. Existing tied arch bridge was collapsed in Taiwan in 2019. It is reported that cable corrosion is the one of the main reasons to trigger the entire bridge collapsed. In this study, the numerical bridge model inspired by the Taiwan arch bridge was designed for analyzing the dynamic analysis of chain reaction failure considering with the cable corrosion. The corrosion of cable is represented by the decreasing of yield stress and breakage strain, and the first ruptured cable which is represented by the decreasing tensile force instantly. According to this analysis, if the cables are corroded significantly, the chain reaction failure would be occurred.</p>

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.