Abstract

Variants of designs of hermetic centrifugal extractors whose drive contains a cylindrical magnetic coupling are presented. A frequency converter (inverter) with the standard torque-limiting function was used for reliable startup of centrifugal extractors with an asynchronous electric motor. The proposed centrifugal extractors have been tested successfully on a production stand. No failures attributable to the magnetic coupling were recorded.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.