Abstract

IntroductionCardiac output/pulmonary blood flow measurement is an important way to assess patients during the perioperative period, as well as patients who are critically ill. Current methods of assessing cardiac output have limitations. One indicator of cardiac output may be the expired carbon dioxide (CO2) partial pressure response to intravenous sodium bicarbonate (IVSB), which is rapidly converted to CO2.MethodsWe conducted an initial evaluation of the relationship between expired CO2 partial pressure and blood flow after a bolus of IVSB. To assess this relationship, we used a cardiopulmonary bypass circuit with predetermined blood flows in a laboratory trial and then assessed 18 patients undergoing surgery requiring cardiopulmonary bypass.ResultsFor the laboratory portion of this pilot study, higher peak expired CO2, faster time to reach peak, higher area under the curve, and greater kurtosis of peak were observed at higher cardiac output flow rates, and higher mean expired CO2 was significantly associated with higher flow rates (p < 0.001). In the human study, higher mean (p = 0.023) and peak expired CO2 (p = 0.028) were both significantly associated with higher cardiac output flow rates.ConclusionsThis technique may be a way to intermittently assess cardiac output or improve accuracy when used in conjunction with other continuous output monitors.

Highlights

  • Cardiac output/pulmonary blood flow measurement is an important way to assess patients during the perioperative period, as well as patients who are critically ill

  • One indicator of cardiac output may be the expired carbon dioxide (CO2) partial pressure response to intravenous sodium bicarbonate (IVSB), which is rapidly converted to CO2

  • For the laboratory portion of this pilot study, higher peak expired CO 2, faster time to reach peak, higher area under the curve, and greater kurtosis of peak were observed at higher cardiac output flow rates, and higher mean expired CO2 was significantly associated with higher flow rates (p < 0.001)

Read more

Summary

Introduction

Cardiac output/pulmonary blood flow measurement is an important way to assess patients during the perioperative period, as well as patients who are critically ill. Current methods of assessing cardiac output have limitations. One indicator of cardiac output may be the expired carbon dioxide (CO2) partial pressure response to intravenous sodium bicarbonate (IVSB), which is rapidly converted to CO2

Methods
Results
Conclusions
Materials And Methods
Discussion
Disclosures
Marik PE
Breen PH
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.