Abstract
A rule-based scheme is investigated for capacitor voltage balancing in a multilevel flying capacitor inverter (MFCI). Without using voltage feedback, the scheme determines the best switching pattern for maintaining nil mean current in all capacitors, hence minimising the capacitor voltage fluctuation. The method is developed to work with the selective harmonic elimination (SHE) technique for sinusoidal voltage generation applied to control static VAR compensators. The method has been designed using a four-cell five-level MFCI as an example. The selected pattern has been shown to give superior performance in load-voltage total-harmonies distortion level and mean capacitor voltage fluctuation. The method is validated experimentally for this form of MFCI.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.