Abstract

The cascaded H-bridge low-capacitance static com- pensator (LC-StatCom) uses relatively small capacitors subjected to large voltage oscillations. When a capacitor degrades, its capacitance differs from the nominal value, and this deteriorates the StatCom operation and safety. This is an important reason to monitor the capacitors condition in StatComs. This letter presents a detailed analysis of the capacitor voltage oscillations and their dependence on the capacitance values. The analysis allows monitoring the condition of the capacitors using a closed- loop approach that feedbacks the error in voltage oscillations. The proposed method is a hardware-free online solution for ca- pacitor condition monitoring (CCM) in LC-StatComs. The letter presents simulation and experimental results that corroborate the effectiveness of the proposed CCM loop.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.