Abstract

Summary A method is described for implanting and maintaining cannulae in the central hepatic vein, the portal vein and a mesenteric vein in adult dairy cows. Blood flow rates in the hepatic and portal veins were measured using indicator dilution techniques. Hepatic venous blood flow rate was approximately 30 l/min (54 ml/min per kg body wt.) in a non-lactating cow. Starvation for 5 days caused this value to fall by about 40%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.