Abstract

Statement of problemMilling is a well-established method for manufacturing prosthetic frameworks. However, information about the influence of ceramic veneer and spark erosion on the accuracy of the all-on-six complete-arch fixed frameworks manufactured from different materials is lacking. PurposeThe purpose of this in vitro study was to compare the accuracy of milled complete-arch fixed frameworks with zirconia, cobalt-chromium, and titanium at different steps of their manufacturing process and the influence of mechanical cycling. Material and methodsFifteen milled complete-arch fixed frameworks, supported by 6 implants, were made in zirconia, cobalt-chromium, and titanium (n=5). The fit was measured by the single-screw test protocol. Stress was measured by photoelastic analysis. The loosening torque was evaluated by tightening the screws, retightening them after 10 minutes, and then evaluating the loosening torque 24 hours later. Thereafter, all frameworks received ceramic veneer, and the previous tests were repeated. Cobalt-chromium and titanium frameworks received spark erosion after ceramic veneer, and all analyses were repeated. Before and after mechanical cycling, loosening torque was evaluated. The results were subjected to 2-way repeated-measures ANOVA and the Bonferroni test (α=.05). ResultsTitanium presented higher fit values than zirconia (P=.037) and similar to cobalt-chromium frameworks (P>.05) at baseline. After ceramic veneer, higher fit levels were observed for zirconia (P=.001) and cobalt-chromium (P=.008). Titanium showed higher stress values (P<.05) regardless of time. Baseline for all materials presented lower stress values (P<.05). Higher loosening torque values were found for the titanium group at baseline (P<.001) and after ceramic veneer (P<.001). Spark erosion improved fit and loosening torque values only for cobalt-chromium (P<.05). Mechanical cycling did not influence the loosening torque (P>.05). ConclusionsTitanium milled complete-arch fixed frameworks presented poorer fit values than zirconia, although the loosening torque at baseline was higher. Ceramic veneer increased the fit levels for zirconia and cobalt-chromium, decreased the loosening torque values for cobalt-chromium, and enhanced stress levels. Spark erosion can be a reliable technique to improve fit and loosening torque for cobalt-chromium frameworks. Mechanical cycling did not decrease loosening torque.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.