Abstract

Deposition loss of particles in air sampling conduit causes the error in estimation of aersol concentration in air. This paper describes the calculation on deposition loss in a straight conduit caused by the gravitational settling and the thermal diffusion in laminar flow and the eddy diffusion in turbulent flow and discusses air flow rates in a conduit for minimizing the deposition loss.The calculation using a computer was made based on the semiempirical equations for the deposition loss formulated by other authors. The results show that the deposition loss for particles of 1g/cm3 density and 1μ diameter in a conduit of 2cm diameter and 10, 000cm long is within 10% in the flow rate of 40 to 400l/min (Reynolds number 3, 000-30, 000).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.