This paper presents a method to calibrate pipe roughness coefficient (i.e., Manning n-factor) with genetic algorithm (GA) under multiple loading conditions. Due to the old pipe age as well as deleting valves and blends in the skeleton of distribution network, most of the pipes in hydraulic model of practical water distribution system (WDS) are rough. The commonly used Hazen-Williams C-factor is therefore replaced by Manning n-factor in calibrating WDS hydraulic model. Adjustment to GA is designed, and the program efficiency is improved. A case study shows that the adjustment can save 60% of the total runtime. About 90% of the relative differences between simulated and observed pressures at monitoring locations are lower than 3%, which suggests that the proposed adjustment to the calibration is efficient and effective.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.