Abstract

On-line monitoring of flow rate is rather important to evaluate the water consumption of the pump-turbine and the overall efficiency of the pumped storage station. Flow rate can be worked out based on the flow differential pressure measured in the flow passage and coefficients determined on model test. But the coefficients must be calibrated to obtain the reliable flow rate. As thermodynamic method is a common way to measure the discharge of prototype pump-turbine, site test is carried out on a vertical pump-turbine with 600 m rated head to calibrated the coefficients in this paper. Measuring devices are designed to satisfy both the turbine and pump operating conditions, and test results of flow rate at both turbine and pump operating conditions are presented and show that the calibrated coefficients are different to the predicted values. The calibrated results indicate the importance of site calibration on prototype turbine to ensure the monitoring validity on real-time flow rate.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.