Abstract

IntroductionTo determine time spent at different physical activity intensities, accelerometers need calibration. The aim of this study was to develop and cross-validate intensity thresholds for the Actigraph GT3X+ accelerometer for wrist and hip placement in four-year-old children.MethodsIn total 30 children (49 months, SD 3.7) were recruited from five preschools in Stockholm. Equipped with an accelerometer on the wrist and another on the hip, children performed three indoor activities and one free-play session while being video recorded. Subsequently, physical activity intensity levels were coded every 5th second according to the Children’s Activity Rating Scale. Receiver Operating Characteristic (ROC) curves was used to develop wrist and hip intensity thresholds, the upper threshold for sedentary, and lower threshold for moderate-to-vigorous physical activity (MVPA), for the vertical axis (VA) and for the vector magnitude (VM). A leave-one-out method was used to cross-validate the thresholds.ResultsIntensity thresholds for wrist placement were ≤ 178 (VA) and ≤ 328 (VM) for sedentary and ≥ 871 (VA) and ≥ 1393 (VM) counts/5 seconds for MVPA. The corresponding thresholds for hip placement were ≤ 43 (VA) and ≤ 105 (VM) for sedentary and ≥ 290 (VA) and ≥ 512 (VM) for MVPA. The quadratic weighted Kappa was 0.92 (95% CI 0.91–0.93) (VA) and 0.95 (95% CI 0.94–0.96) (VM) for the wrist-worn accelerometer and 0.76 (98% CI 0.74–0.77) and 0.86 (95% CI 0.85–0.87) for the hip-worn.ConclusionUsing wrist placement and the VM when measuring physical activity with accelerometry in 4-year-old children is recommended.

Highlights

  • To determine time spent at different physical activity intensities, accelerometers need calibration

  • Data underlying the results described in our manuscript are available from: Elin Johansson, Division of Physiotherapy, Department of Neurobiology, Care Science and Society, Karolinska Institutet, Alfred Nobels Allé 23, 141 83 Huddinge, Sweden

  • Intensity thresholds for wrist placement were 178 (VA) and 328 (VM) for sedentary and ! 871 (VA) and ! 1393 (VM) counts/5 seconds for moderate-to-vigorous physical activity (MVPA)

Read more

Summary

Introduction

To determine time spent at different physical activity intensities, accelerometers need calibration. The aim of this study was to develop and cross-validate intensity thresholds for the Actigraph GT3X+ accelerometer for wrist and hip placement in four-year-old children

Methods
Results
Conclusion
Method
Procedures
Discussion
Strengths and limitations
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.