Abstract

The magnetic field of the 168 kA aluminum reduction cell was calculated with the software ANSYS in our study. The calculated results showed that the magnetic line of the aluminum and electrolyte in cell formed a clockwise swirl. The X and Z magnetic intensity of aluminum was similar with the antisymmetric distribution and the magnetic intensity vector of aluminum reduced along the -Z axis. The X, Y and Z magnetic intensity in the electrolyte under the anode bottom was similar with the antisymmetric distribution along short axis (Y axis), long axis (X axis) and short axis (Y axis), respectively. The magnetic intensity vector of electrolyte in the gap of the anode was higher than that under the anode bottom. The X and Z magnetic intensity in the interface of melt was also similar with the antisymmetric distribution. The numerical simulations with ANSYS have the important references for project analysis and diagnose.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.