Abstract
In hearts with left bundle branch block (LBBB), both atrioventricular (AV) delay and interventricular (VV) interval determine left ventricular (LV) pump function in cardiac resynchronization therapy (CRT). The optimal combination of AV delay and VV interval currently is determined by extensive hemodynamic testing. The purpose of this study was to investigate whether the effective VV interval (VV(eff)) can be used to optimize AV delay and VV interval. In eight canine hearts with chronic LBBB, LV pacing was performed at various AV delays as well as biventricular pacing at multiple AV delays and VV intervals. LV pump function was assessed from LVdP/dt(max) and stroke volume (conductance catheter). Interventricular asynchrony was calculated from the timing difference between upslope of LV and RV pressure curves. VV(eff) was defined as the time delay between activation of the RV apex and LV lateral wall, irrespective of the source of RV activation (RV pacing or intrinsic conduction). VV(eff) was determined from pacemaker settings and surface ECGs recorded during biventricular pacing at various AV delays (positive values denote LV preexcitation). For all animals, the relationship between VV(eff) and LVdP/dt(max) as well as LV stroke work was parabolic. Maximal improvement in LVdP/dt(max) was similar during LV pacing, simultaneous biventricular pacing, and sequential biventricular pacing and was obtained at similar values of VV(eff). VV(eff) was strongly correlated with interventricular asynchrony (R = 0.97 +/- 0.03). Optimum LVdP/dt(max) occurred at VV(eff) ranging from -24 to 12 ms (mean -6 +/- 13 ms). For each experiment, the optimal VV(eff) was virtually equal to the value halfway between its minimum (during LV pacing at short AV delay) and maximum (during LBBB) value (R = 0.91). Use of VV(eff) facilitates determination of the best combination of AV delay and VV interval during biventricular pacing. For each individual heart, VV(eff), resulting in optimum LV pump function, can be estimated using surface ECGs recorded during biventricular pacing.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.