Abstract

The dose accumulated in bricks exposed to gamma radiation can be measured as a function of depth using luminescence methods. The dependence of dose on depth has the potential of providing information on the energy as well as on the angular distribution of the incident radiation, which could give indications on the configuration of the radiation sources. A prerequisite for such an analysis is a comprehensive knowledge on the dependence of dose on depth for different source energies and for specific source configurations. Depth dose distributions in brick walls have been calculated by Monte Carlo simulations for a source distribution on a wall, for a source distribution on the ground and for a parallel photon beam, for source energies ranging from 140 keV to 1600 keV. It is shown that depth dose distributions depend substantially on source configuration and energy. Depth dose distributions measured in ceramic material irradiated in the laboratory and in a brick from a contaminated area are compared with results of Monte Carlo calculations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.