Abstract

In this study, fluoridated hydroxyapatite coatings are prepared on Ti6Al4V alloy substrate through sol–gel method. The bonding strength is evaluated through two different methods: pull-out method and scanning scratch method. Both results show F incorporation could effectively increase the bonding between coating and substrate. It is found that the pull-out results are actually compounds of adhesion failure, cohesive failure and glue failure; while the critical loads in scanning scratch show only the coating-matrix adhesion strength. It is suggested that scanning scratch test is more suitable to evaluate the bonding strength of bioactive ceramic coatings.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.