Abstract

To evaluate the bond behavior between glulam and GFRP rods, applied according to the near-surface mounted strengthening technique, an experimental program composed of beam and direct pullout tests was carried. In this experimental program three main variables were analyzed: the GFRP type, the GFRP location into the groove, and the bond length. From the monitoring system it was registered the loaded and free end slips, and the pullout force. Based on these experimental results, and applying an analytical–numerical strategy, the local bond stress–slip relationship was calculated. In this work the tests are described, the obtained results are presented and discussed, and the applicability of the inverse analysis to obtain the local bond law is demonstrated.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.