Abstract

The purpose of the work was to establish a reliable procedure for blood sampling from central venous catheters with a minimal loss of blood. Based on previous studies of potassium measurements, the routine procedure had been to discard 12 ml of blood. In order to clear the catheter from substances from the infusion including potassium, the catheters were first flushed with 5 ml of saline. Repeated samples in fractions of 3 ml for hematological analyses (ethylenediaminetetraacetic acid plasma; seven patients), coagulation tests (citrate plasma; seven patients) and for serum measurements (eight patients) showed that a discarded volume of 3 ml corresponding to at least six times the dead-space of the catheters was sufficient after initial flushing with saline.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.