Abstract

The objectives are to compare lead blood concentrations in veterinary workers using lead shielding with concentrations in a control population, to measure hand surface lead before and after use of shielding, and to compare hand surface lead with and without the use of disposable gloves worn under hand shielding. Blood and hand wipe samples were analyzed for lead using inductively coupled plasma mass spectrometry. There was no difference in blood lead between exposed and control groups. After lead glove use, 69% (18/26) of hand surface lead samples from workers not using disposable gloves were greater than 500 μg, 42% (11/26) were greater than 1000 μg, and 12% (3/26) were greater than 2000 μg. If lead shielding use is unavoidable, disposable gloves should be worn, and skin should be decontaminated after use.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.