Abstract
Abstract Radiation blistering of niobium surfaces has been investigated for normally incident He+ and D+ projectiles. For the He+, the bombarding energies were 0.5 and 1.5 MeV, the targets were both monocrystalline and polycrystalline niobium at room temperature and at 900°C, and the total dose was from 0.01 to 1.0 C/cm2. For cold-worked samples at room temperature, 0.5-MeV He+ ions produced large blisters (up to 500 μm in diameter), many of which were ruptured; 1.5-MeV He+ ion implantation produced one big blister covering most of the irradiated area. For the D+ ion implantation, the bombarding energies were 0.250 and 0.5 MeV and the targets were all polycrystalline. Implanting 0.250-MeV D+ ions in annealed polycrystalline Nb at 700°C produced small blisters for doses ranging from 1.6 to 3.0 C/cm2. Preliminary results on the skin thicknesses of ruptured blisters indicate a close relationship between the thickness and both the projected range of the ions and the peak in the defect distributions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.