Abstract

ContextIncorporation of bipolar technology in transurethral resection (TUR) of the prostate (TURP) potentially offers advantages over monopolar TURP (M-TURP). ObjectiveTo evaluate the evidence by a meta-analysis, based on randomized controlled trials (RCTs) comparing bipolar TURP (B-TURP) with M-TURP for benign prostatic obstruction. Primary end points included efficacy (maximum flow rate [Qmax], International Prostate Symptom Score) and safety (adverse events). Secondary end points included operation time and duration of irrigation, catheterization, and hospitalization. Evidence acquisitionBased on a detailed, unrestricted strategy, the literature was searched up to February 19, 2009, using Medline, Embase, Science Citation Index, and the Cochrane Library to detect all relevant RCTs. Methodological quality assessment of the trials was based on the Dutch Cochrane Collaboration checklist. Meta-analysis was performed using Review Manager 5.0. Evidence synthesisSixteen RCTs (1406 patients) were included. Overall trial quality was low (eg, allocation concealment and blinding of outcome assessors were poorly reported). No clinically relevant differences in short-term (12-mo) efficacy were detected (Qmax: weighted mean difference [WMD]: 0.72ml/s; 95% confidence interval [CI], 0.08–1.35; p=0.03). Data on follow-up of >12 mo are scarce for B-TURP, precluding long-term efficacy evaluation. Treating 50 patients (95% CI, 33–111) and 20 patients (95% CI, 10–100) with B-TURP results in one fewer case of TUR syndrome (risk difference [RD]: 2.0%; 95% CI, 0.9–3.0%; p=0.01) and one fewer case of clot retention (RD: 5.0%; 95% CI, 1.0–10%; p=0.03), respectively. Operation times, transfusion rates, retention rates after catheter removal, and urethral complications did not differ significantly. Irrigation and catheterization duration was significantly longer with M-TURP (WMD: 8.75h; 95% CI, 6.8–10.7 and WMD: 21.77h; 95% CI, 19.22–24.32; p<0.00001, respectively). Inferences for hospitalization duration could not be made. PlasmaKinetic TURP showed an improved safety profile. Data on TUR in saline (TURis) are not yet mature to permit safe conclusions. ConclusionsNo clinically relevant differences in short-term efficacy exist between the two techniques, but B-TURP is preferable due to a more favorable safety profile (lower TUR syndrome and clot retention rates) and shorter irrigation and catheterization duration. Well-designed multicentric/international RCTs with long-term follow-up and cost analysis are still needed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.