Abstract
A biomechanical comparison study using finite element method. The aim of this study was to investigate effects of different dynamic stabilization devices, including pedicle-based dynamic stabilization system (PBDSS) and interspinous process spacer (ISP), used for topping-off implants on biomechanical responses of human spine after lumbar interbody fusion. Topping-off stabilization technique has been proposed to prevent adjacent segment degeneration following lumbar spine fusion. PBDSS and ISP are the most used dynamic stabilizers for topping-off instrumentation. However, biomechanical differences between them still remain unclear. A validated, normal FE model of human lumbosacral spine was employed. Based on this model, rigid fusion at L4-L5 and moderately disc degeneration at L3-L4 were simulated and used as a comparison baseline. Subsequently, Bioflex and DIAM systems were instrumented at L3-L4 segment to construct PBDSS-based and ISP-based topping-off models. Biomechanical responses of the models to bending moments and vertical vibrational excitation were computed using FE static and random response analyses, respectively. Results from static analysis showed that at L3-L4, the response parameters including annulus stress and range of motion were decreased by 41.6% to 85.2% for PBDSS-based model and by 6.3% to 67% for ISP-based model compared with rigid fusion model. At L2-L3, these parameters were lower in ISP-based model than in PBDSS-based model. Results from random response analysis showed that topping-off instrumentation increased resonant frequency of spine system but decreased dynamic response of annulus stress at L3-L4. PBDSS-based model generated lower dynamic stress than ISP-based model at L3-L4, but the dynamic stress was higher at L2-L3 for PBDSSbased model. Under static and vibration loadings, the PBDSSbased topping-off device (Bioflex) provided a better protection for transition segment, and likelihood of degeneration of supraadjacent segment might be relatively lower when using the ISPbased topping-off device (DIAM).Level of Evidence: 5.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.