Abstract

Basicervical femoral neck fractures are challenging fractures in geriatric populations. The goal of this study was to determine whether compression hip screw (CHS) constructs are superior to cephalomedullary constructs for the treatment of basicervical femoral neck fractures. Thirty cadaver femurs were osteotomized and received a CHS with derotation screw, a long cephalomedullary nail (long Gamma nail), or a short cephalomedullary nail (short Gamma nail). All constructs were loaded dynamically in compression until dynamic failure. All failed CHS constructs demonstrated superior femoral head cutout. In the long Gamma nail and short Gamma nail groups, constructs failed by nail cutout through the medial wall of the trochanter or rotationally. Normalized fluoroscopic distance was found to increase markedly with an increasing cycle count when considering all treatment groups. Given our results and those of previous studies, we could not determine superiority of one implant and recommend that surgeons select fixation constructs based on the individual patient's anatomy and the surgeon's comfort with the implant.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.