Abstract
ABSTRACT The effect of the number of stages and cell carrier loading on the steady-state and startup performance of a continuous pulsed plate bioreactor with glass beads as the cell carrier material for biodegradation of phenol in wastewater using immobilized Nocardia hydrocarbonoxydans has been studied. It was found that the performance of the pulsed plate bioreactor during startup and at steady state can be improved by an increase in cell carrier loading, number of stages, total plate stack height, and with a decrease in plate spacing. The startup time for the continuous bioreactor can be decreased by increasing the number of preacclimatization steps for the cells. The attainment of steady effluent phenol concentration can be considered as an indication of steady state of the continuous bioreactor, as when phenol concentration attained a steady value, biofilm thickness, and the attached biomass dry weight also attained a constant value.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.