Abstract

Measurement of the absolute bioavailability of phenytoin (PHT) derived from test doses of phenytoin prodrug (PPD) at therapeutic PHT serum concentrations is complicated by two problems: 1) the area under the serum concentration versus time curve (AUC) produced by a given size of test dose will vary directly with background PHT serum concentration due to the nonlinear pharmacokinetic properties of PHT; 2) PPD is more water soluble than PHT, making renal excretion of PPD more likely. The authors describe a double-stable isotope method that obviates these two problems. Using only six subjects, the authors were able to demonstrate bioequivalence of PHT derived from intravenous PPD with intravenous PHT by current FDA standards for AUC ratio of test/reference formulation (90% confidence intervals between 0.80 and 1.20; ratio > or = 0.80 in > or = 80% of subjects; statistical power to detect a difference of 0.20 with a probability of 0.80).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.