Aim.The main purpose of this study was to develop a simple, precise, rapid and accurate method for the quantification of metoprolol and meldonium in human plasma. Materials and methods. The resolution of peaks of metoprolol was best achieved with Discovery C18, 50 × 2.1 mm, 5 μm column and meldonium - ZORBAX HILIC Plus, 50 × 2.1 mm, 3.5 μm column. Samples of metoprolol were chromatographed in a gradient mode (eluent A (acetonitrile – water – formic acid, 5 : 95 : 0.1 v/v), eluent B (acetonitrile – formic acid, 100 : 0.1 v/v)). The initial content of the eluent B is 0%, which increases linearly by 1.0 min to 100% and to 1.11 min returns to the initial 0%. The mobile phase was delivered at a flow rate of 0.400 mL/min into the mass spectrometer ESI chamber. The injection volume was 5μl. Samples of meldonium were chromatographed in a isocratic using mobile phase water – acetonitrile – ammonium formate buffer 200 мМ, 20 : 75 : 5 v/v). Results.The total chromatographic run time was 2.0 minutes and the elution of metoprolol, meldonium and IS occurred at ~1.39 and 1.18 minutes, respectively.A linear response function was established at 2 - 200 ng/mL for metoprolol and 50 -5000 ng/mL for meldonium in human plasma. The% mean recovery for metoprolol in LQC, MQC and HQC was 99.0%, 107.5% and 96.8%, for meldonium in LQC, MQC and HQC was 94.1%, 100.2% and 93.1% respectively. The lowest concentration with the RSD <20% was taken as LLOQ and was found to be 2.31 ng/mL for metoprolol, 47.70 ng/mL for meldonium. The % accuracy of LLOQ samples prepared with the different biological matrix lots were found 115.4% for metoprolol and 95.5% for meldonium, which were found within the range of 80.00–120.00% for the seven different plasma lots. % CV for LLOQ samples was observed as 12.8% and 7.7% respectively, which are within 20.00% of the acceptance criteria. Conclusion.A rapid method was developed for simultaneous determination of metoprolol and meldonium in human plasma. The method was strictly validated according to the ICH guidelines. Acquired results demonstrate that proposed strategy can be effortlessly and advantageously applied for routine examination of metoprolol and meldonium in human plasma.

Highlights

  • Metoprolol (Fig. 1) is a beta1-selective adrenoceptor blocking agent, for oral administration, available as extended-release tablets

  • The mobile phase was delivered at a flow rate of 0.400 mL/min into the mass spectrometer ESI chamber(Logoyda 2019).For determination of meldonium we used ZORBAX HILIC Plus, 50 × 2.1 mm, 3.5 μm column and mobile phase water –acetonitrile – ammonium formate buffer200 мМ, 20 : 75 : 5 v/v)

  • Meldonium can be perfectly determined by HILIC chromatography and metoprolol by conventional reversed-phase HPLC

Read more

Summary

Introduction

Metoprolol (Fig. 1) is a beta1-selective (cardioselective) adrenoceptor blocking agent, for oral administration, available as extended-release tablets. Metoprolol succinate extended-release tablet has been formulated to provide a controlled and predictable release of metoprolol for once-daily administration. The tablets comprise a multiple unit system containing metoprolol succinate in a multitude of controlled release pellets. Metoprolol is a propanolamine that is 1-(propan-2-ylamino) propan-2-ol substituted by a 4-(2-methoxyethyl)phenoxy group at position 1. It has a role as a beta-adrenergic antagonist, an antihypertensive agent, a xenobiotic and an environmental contaminant. It is a propanolamine, an aromatic ether, a secondary alcohol and a secondary amino compound. Metoprolol is used for a number of conditions, including hypertension, angina, acute myocardial infarction, upraventricular tachycardia, ventricular tachycardia, congestive heart failure, and prevention of migraine headaches

Objectives
Methods
Results

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.