Abstract

Technologies for monitoring meat spoilage are important to ensuring consumer safety. As dimethyl sulfide (DMS) is a reliable marker for meat freshness, sensitive and selective DMS sensors are of great interest. Herein, two trinuclear cyano-bridged bimetallic donor–acceptor ensembles, FeII(bpy)2(CN)2–[PtII(DMSO)Cl2]2 (1) and FeII(bpy)2(CN)2–[AuICl]2, were synthesized, and corresponding solid-supported sensors were fabricated to determine the effect of the acceptor metal (MA) on DMS detection. Changing MA from AuI to PtII improved the sensitivity and selectivity owing to changes in the relative thermodynamic stabilities of the complex and MA–DMS adduct. When applied to real meat samples, 1 exhibited a linear spectroscopic response to DMS, even in the presence of interfering compounds, with a method detection limit of 1.0 ppm. The total bacteria count and gas chromatography–mass spectrometry results revealed that the spectroscopic signal generated by 1 correlated with the microbial growth level and DMS concentration during meat spoilage.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.