Abstract

Improving imaging speed has always been the focus of research in CT technology, which is related to the radiation dose and imaging quality of moving organs, including heart and blood vessels. However, it is difficult to achieve further improvement by increasing the rotation speed of the gantry due to its structural strength limitation. Differing from the conventional CTs, the static CT employs dozens of ray sources to acquire projection data from different angular ranges, and each source only needs to be rotated in a small range to finish a full 360° scan, thus greatly increasing the scanningspeed. As sources of static CT need to be evenly distributed over 360°, the sources and detectors have to be arranged on two parallel rings independently. Such a geometry can be considered as a special case of CT systems with a significantly large cone angle, that is, a part of the detector is missing in the vicinity of the mid-plane. Due to restriction of upper and lower bounds of the cone angle of the static CT, there are uneven projection data varying in each portion of the reconstruction volume, the conventional analytical or iterative reconstruction methods may introduce artifacts in the reconstructedoutcomes. Following the weighting approach extended FDK (xFDK) by Grimmer etal., we propose an improved bilateral xFDK algorithm (bixFDK), which focuses on the reconstruction of the expanded volume. With the same philosophy as xFDK in terms of weighting function design, bixFDK takes the longitudinal offset of the detector with respect to the source into consideration, making our method applicable to a wide range of CT geometries, especially for the static CT. Based on the proposed bixFDK, a new iterative scheme bixFDK-IR is also constructed to extend the applications to a wide range of scan protocols such as sparse-viewscan. The proposed method has been validated with the simulated phantom data and the actual clinical data of the static CT, and demonstrates that it can ensure good image quality and enlarge the reconstruction volume in z-direction of the staticCT. The bixFDK algorithm is an ideal reconstruction approach for static CT geometry, and the iterative scheme of bixFDK-IR is applicable to a wide range of CT geometries and scan protocols, thus providing a wide range of applicationscenarios.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.