Abstract
The Endo-Model rotating-hinge prosthesis is preferably indicated as a primary implant in patients with advanced axial deviation of the lower limbs or unstable knees with severe bone defects. Outcomes were studied in 111 knees, operated in a three-year period; the mean followup was 28 months. Joint balance enhancement and limbs mechanical axis correction were achieved after surgery. There were 6 deep infections and 16 patients referred postoperative anterior knee pain. WOMAC index scores disaggregated by gender and BMI showed better outcomes in obese patients (specifically, those with a BMI of 35–40 kg/m2) and in men. Although the lack of a control group did not allow definite conclusions and despite a nonnegligible complication rate, our results reveal that the Endo-Model total knee arthroplasty can be a useful tool to deal with severe and morbid obese patients affected of severe gonarthrosis associated with marked axial deviations, ligament instability, or bone defects.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.