Abstract

Central MessageCustomized conduits could be a great advance for the Fontan procedure. With the use of magnetic resonance imaging data, ideal grafts can be created for optimum efficiency; the clinical impact of these constructs is yet unknown.See Article page 1734. Customized conduits could be a great advance for the Fontan procedure. With the use of magnetic resonance imaging data, ideal grafts can be created for optimum efficiency; the clinical impact of these constructs is yet unknown. See Article page 1734. An image often used as the introductory slide for any lecture on the Fontan procedure displays a dizzying array of various versions of the operation in its evolution since inception.1Fontan F. Baudet E. Surgical repair of tricuspid atresia.Thorax. 1971; 26: 240-248Crossref PubMed Scopus (2051) Google Scholar From initial atriopulmonary connection to “leaner and meaner” prosthetic tube graft, all seek to optimize passive pulmonary blood flow. Indeed, any perturbations in the connection can lead to distorted flow distribution, poor pulmonary arterial growth, stasis/thrombosis, or power loss and resultant reduction in cardiac output in this classically unforgiving physiology. Accordingly, recent strategies have sought to use flow dynamics in an effort to guide preoperative planning and customize the Fontan pathway for individual patients.2Kanter K.R. Haggerty C.M. Restrepo M. deZelicourt D.A. Rossignac J. Parks W.J. et al.Preliminary clinical experience with a bifurcated Y-graft Fontan procedure—a feasibility study.J Thorac Cardiovasc Surg. 2012; 144: 383-389Abstract Full Text Full Text PDF PubMed Scopus (34) Google Scholar, 3Haggerty C.M. deZelicourt D.A. Restrepo M. Rossignac J. Spray T.L. Kanter K.R. et al.Comparing pre- and post-operative Fontan hemodynamic simulations: implications for the reliability of surgical planning.Ann Biomed Eng. 2012; 40: 2639-2651Crossref PubMed Scopus (44) Google Scholar However, these tactics have been partially limited by the need to select prosthetic grafts “off the rack”—the dream of a tailor-made conduit, optimized for specific anatomy and flow efficiency, has remained elusive until now. In this issue of the Journal, Siallagan and colleagues4Siallagan D. Loke Y. Oliveri L. Opfermann J. Ong C.S. deZelicourt D. et al.Virtual surgical planning, flow simulation, and 3-dimensional electrospinning of patient-specific grafts to optimize Fontan hemodynamics.J Thorac Cardiovasc Surg. 2018; 155: 1734-1742Abstract Full Text Full Text PDF PubMed Scopus (33) Google Scholar describe an important first step toward this goal. Their analysis first pitted cardiac magnetic resonance imaging data from 2 patients after Fontan completion against idealized virtual models (both tube and bifurcated conduits) and later used models in a 4-chamber flow loop, as well for the basis of 3-dimensional tissue-engineered vascular grafts (with the anticipation of in vivo applications in the future). On the basis of these data, one of their patients would theoretically enjoy the benefit of a bifurcated graft—with very specific distal anastomotic sites for each limb—whereas the other saw little advantage over a simple (albeit customized) tube graft. Indeed, the term “advantage” here must be used somewhat cautiously, because it is only speculation that the creation of more balanced hepatic flow distribution portends a better outcome; in a more fundamental way, “power loss” in this investigation was used as a surrogate of cardiac output, where obviously in the human condition it is only one of its many determinants. Additionally, the fundamental assumptions of a rigid Fontan geometry and of laminar flow (ie, not during exercise or across full cardiac cycles) disclose obvious next areas of focus for “version 2.0”. Without question, the proof will be in the Fontan pudding. Thrombogenicity has always been a central concern with both tissue-engineered vascular graft conduits and bifurcated polytetrafluoroethylene (PTFE) grafts—the former because of the material, the latter because of each limb's limited cross-sectional area. Whether patients (or animals) actually derive benefit from a more balanced and efficient custom-made circuit is still unclear. What is irrefutable, however, is that the Fontan procedure is an imperfect construct applied to a broadly heterogeneous patient population and undoubtedly could be perfected. The “one size fits all” approach that we as a specialty have applied for decades surely needs to enter the era of the bespoke; to this end, the fashionista battle cry may have no better application than in Fontan physiology, because let's face it, “if you look good, you feel good.” Virtual surgical planning, flow simulation, and 3-dimensional electrospinning of patient-specific grafts to optimize Fontan hemodynamicsThe Journal of Thoracic and Cardiovascular SurgeryVol. 155Issue 4PreviewDespite advances in the Fontan procedure, there is an unmet clinical need for patient-specific graft designs that are optimized for variations in patient anatomy. The objective of this study is to design and produce patient-specific Fontan geometries, with the goal of improving hepatic flow distribution (HFD) and reducing power loss (Ploss), and manufacturing these designs by electrospinning. Full-Text PDF Open Archive

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.