Abstract

We performed benchmark calculation for radioactivity activated in a Primary Containment Vessel (PCV) of a Boiling Water Reactor (BWR) by using MAXS library, which was developed by collapsing with neutron energy spectra in the PCV of the BWR. Radioactivities due to neutron irradiation were measured by using activation foil detector of Gold (Au) and Nickel (Ni) at thirty locations in the PCV. We performed activation calculations of the foils with SCALE5.1/ORIGEN-S code with irradiation conditions of each foil location as the benchmark calculation. We compared calculations and measurements to estimate an effectiveness of MAXS library.

Highlights

  • According to the Japanese law, any operating organization of decommissioning of nuclear facilities such as electric power companies needs to submit an application for decommissioning and to receive the authorization

  • We applied MAXS library, which is generated by collapsing with neutron energy spectrum at position, to activation calculation for radioactiveities measured with activation foils in the Primary Containment Vessel (PCV)

  • We performed activation calculations at the locations in the PCV of the Boiling Water Reactor (BWR) where radioactiveities of both Au and Ni were measured as benchmark calculation for MAXS library

Read more

Summary

Introduction

According to the Japanese law, any operating organization of decommissioning of nuclear facilities such as electric power companies needs to submit an application for decommissioning and to receive the authorization. Use of ORIGEN-S cross section library that was developed by collapsing cross sections with a typical neutron energy spectrum of a Light Water Reactor (LWR) is considered to be inappropriate under the condition in the PCV. According to a comparison between the shape of the typical spectrum of a LWR and those of spectra in the PCV of the BWR, it would be inappropriate to apply ORIGEN library, which is generated with the typical spectrum, to activation calculation in the PCV. We applied MAXS library, which is generated by collapsing with neutron energy spectrum at position , to activation calculation for radioactiveities measured with activation foils in the PCV. 1.E+08 1.E+07 1.E+06 1.E+05 1.E+04 1.E+03 1.E+02 1.E+01 1.E+00 1.E-01 1.E-02 1.E-03 1.E-04 1.E-05

Radioactivity measurements with activation foil in the PCV
Calculation results
Summary and conclusions

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.