Abstract

Control valve is one of key elements in processing of a chemical industry and it is one of its important functions is as a flow control of chemical process. The accuracy of control valve opening or traveling is proportional to flow capacity. On the other hand, a leakage of a control valve on its failed position especially for Air to Open-Fail Closed (ATO-FC) type valve can become a disaster. One of critical parameters in Control Valve that impacts to performance and fail-safe position is Bench set range spring in valve’s actuator. This work analyzed this Bench set range impact to the fail-safe position. The force in spring is defined by control valve specification verified by force balance method of control valve. Then the impact of bench set range was analyzed by displacement of spring from spring force equation. At the end, the outcome is displacement data in correlation to the change of bench set range. It helps the repair technician on the maintenance workshop of permissible range when they adjust the bench set range by adjusting spring compression.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.